A thermometer calibration log records regular accuracy checks of the probe thermometers a food business relies on. It helps show that temperature readings can be trusted — which matters when those readings are used to prove cooking, cooling and cold storage are under control. What it includes: Date of the calibration or accuracy check. The thermometer or probe identified (make, model or asset number). The check method used (for example an ice-point test at 0°C). The reading obtained and whether it was within tolerance (commonly ±1°C). Any adjustment, reset or repair made, or whether the probe was taken out of use. Initials of the staff member who checked. How to use it: Identify each probe thermometer you use for food safety checks. Do an ice-point test: sit the probe in a slushy ice-and-water mix and expect close to 0°C. Compare the reading against the expected value and note any difference. If it is outside tolerance (commonly ±1°C), adjust, reset, repair or replace the probe. Record the result and any action, and don't use an out-of-tolerance probe for records. Check accuracy on a regular schedule and keep the log on file. Temperature records are only as reliable as the thermometer that produced them. Standard 3.2.2A requires many businesses to have a temperature measuring device that is readily accessible and accurate — often to ±1°C — so checking and recording accuracy supports every other temperature control. Confirm the device and record requirements that apply with your council or regulator. How do I calibrate a food thermometer? A simple field check is the ice-point test: fill a cup with crushed ice, add a little cold water to make a slush, stir, and insert the probe without touching the sides. A reading close to 0°C suggests the probe is accurate. A boiling-water test (around 100°C at sea level) can also be used. If the reading is off, adjust, reset or replace the probe per the manufacturer's instructions. How accurate should a food thermometer be? For many Australian food businesses, Standard 3.2.2A expects a temperature measuring device accurate to plus or minus 1°C. Checking against a known point like 0°C helps confirm this. If a probe drifts outside that range and cannot be corrected, take it out of service so it isn't used for food safety records. How often should thermometers be calibrated? There is no single rule for every business. Many check accuracy on a regular schedule — for example monthly — and also after a probe is dropped or exposed to extremes. Base the frequency on how heavily the probe is used, and confirm any specific expectations with your food safety program or regulator.

How to use the Thermometer Calibration Log

  1. Identify each probe thermometer you use for food safety checks
  2. Do an ice-point test: sit the probe in a slushy ice-and-water mix and expect close to 0°C
  3. Compare the reading against the expected value and note any difference
  4. If it is outside tolerance (commonly ±1°C), adjust, reset, repair or replace the probe
  5. Record the result and any action, and don't use an out-of-tolerance probe for records
  6. Check accuracy on a regular schedule and keep the log on file

Frequently asked questions

How do I calibrate a food thermometer?

A simple field check is the ice-point test: fill a cup with crushed ice, add a little cold water to make a slush, stir, and insert the probe without touching the sides. A reading close to 0°C suggests the probe is accurate. A boiling-water test (around 100°C at sea level) can also be used. If the reading is off, adjust, reset or replace the probe per the manufacturer's instructions.

How accurate should a food thermometer be?

For many Australian food businesses, Standard 3.2.2A expects a temperature measuring device accurate to plus or minus 1°C. Checking against a known point like 0°C helps confirm this. If a probe drifts outside that range and cannot be corrected, take it out of service so it isn't used for food safety records.

How often should thermometers be calibrated?

There is no single rule for every business. Many check accuracy on a regular schedule — for example monthly — and also after a probe is dropped or exposed to extremes. Base the frequency on how heavily the probe is used, and confirm any specific expectations with your food safety program or regulator.

Free tool: Temperature Log Generator How to Calibrate a Probe Thermometer All free templates Food safety guides

FoodSafety HQ is food safety compliance software for Australian hospitality: temperature monitoring, cleaning records, PEAL allergen management, waste and expiry, and council-ready audits, aligned with the FSANZ Food Standards Code.

About Us Contact Features Pricing Food Safety Compliance Software Food Traceability Software SQF Certification BRCGS Certification Best Food Safety Software (AU) Food Safety Software for Restaurants Food Safety Software for Cafés Food Safety Software for Multi-Site Food Safety Compliance Checklist Food Safety Questions Food Safety Guides Free Record Templates Free Tools Blog Editorial Guidelines Privacy Policy Terms of Service Security Sitemap
Sydney, NSW, Australia

© 2026 Toradigm Pty Ltd, Trading as Food Safety HQ · ABN 70 679 136 577. All rights reserved.

Back to top